PLATH SIR 5115 HF

PLATH SIR 5115 HF Receiver


The HF broadband receiver SIR 5115, covering the frequency range from 0.5 to 30 MHz, represents the benchmark of HF signal interception. It intercepts every signal simultaneously in the complete HF range.

Offering full high-resolution coverage and multiple virtual narrowband receivers, the SIR 5115 replaces entire banks of single channel receivers without compromising blocking dynamic range or intermodulation. This means having fewer receivers produce more signals with less error.

Product PLATH SIR 5115
Delivery RX
Requirement ---
Recommended go2MONITOR
Options:
- Advanced Memory Scan
- Output of 29.5 MHz in channels to 96 kHz
- 240 additional DDC channels (this option could be used twice)
- Graphical user interface WinMON
Use cases Multi Channel Receiver up to 600 Channels
Complete range 0.5- 30 MHz
Training on request
Price ask

Features

  • Excellent dynamic range: IMFDR 105 dB
  • Full interception from 0.5 to 30 MHz
  • High dynamic range due to 7 sub-octave filters
  • Up to 600 virtual narrowband receivers
  • No internal spurious responses

Multi band HF Receiver

Monitor the full HF frequency range with one receiver

Specifications

Feature Data
Frequency range 0.5 - 30 MHz
Tuning resolution (DDC) < 1 Hz
Coherent bandwidth 29.5 MHz, (digital in 40 subbands)
DDC channels 320 channels, wideband IQ 40 x 768 kHz
Preselection 7 high- and low pass filters
Gain control Automatic, manual or automatic with user defined shift (AGC + M)
Maximum input level + 30 dBm (non-destructive)
Noise figure < = 12 dB (without preselection)
MDS (Minimum Detectable Signal) -139 dBm (at 125 Hz resolution, 500 ms integration)
SFDR (Spurious-Free Dynamic Range) typ. 105 dB
> 100 dB (2 - 30 MHz, in-band)
> 95 dB (0.5 - 2 MHz, in-band)
Input IP2 > = 80 dBm (at 0 dBm and with AGC), presel.: off
Input IP3 > = 43 dBm (at 0 dBm and with AGC)
BDR (Blocking Free Dynamic Range) 140 dB/Hz
Full dynamic range 169 dB
IF rejection > 140 dB
Image rejection > 90 dB
Internal spurious None
Frequency stability +/- 10E-7
Frequency drift < +/- 5* 10E-7 ageing / year
Phase noise < -150 dBc / Hz at 10 kHz offset
VSWR < 2 : 1
Antenna input 5 x N-connector female (nominal impedance 50 Ohm)
Input for external reference frequency BNC-female (10 MHz)
Input for time synchronization BNC: pulse per second (PPS)
Network interface 7 x Gigabit Ethernet (for control and data)
Service connection RS-232
Operating voltage 90 - 264 VAC (50 / 60 Hz)
Maximum power consumption 400 VA
Built In Test Equipment (BITE) For every internal module, via SNMP interface
MTBF (according to MIL-HDBK) At least 10,000 hours
Operating temperature 0 grd C to +50 grd C
Storage temperature -40 grd C to +70 grd C
Humidity < = 85 % (non-condensing)
Environmental standards maintained EN61010-1:2002, EN61000-6-2:2002, EN61000-6-3:2002
Width 19 inch (482.6 mm)
Height 3 RU (133.5 mm)
Depth 605 mm
Weight 15.3 kg